Single Phase Inductors whit DC Filters – Chopper Coil

  IEC-EN 60289 EC Electrical features: Inductance: 3.6 mH Rated current: 1570 Amp. Peak current: 2225 Amp. 500 Hz ripple: 300 Amp, PK/PK Rated operational voltage: 5300 Vcc Dielectric strength: 15 KV/50HZ/60 sec. Weight: 2850 Kgs. APPLICATION DC Filter (chopper coil) * Due to the wide range available, we can offer the inductor you need on request.
More

Stabilized voltage and current sources

ELECTRICAL CHARACTERISTICS : INPUT: 400V OUTPUT 1: 0 A 60 Vac - 700 Amp OUTPUT 2: 60 A 120 Vac - 350 Amp REMOTE LOCAL CONTROL CURRENT REGULATION VOLTAGE REGULATION RANGE 60V / 120V MEASUREMENTS: 1200 x 800 x 500 mm (H x W x L) FORCED VENTILATION PROTECTION: IP.20 APPROXIMATE WEIGHT: 500 Kg * Debido a la amplia gama existente, sobre demanda podemos ofrecer la fuente que usted desee.
More

Three-phase systems

Lighting Flow Regulation Systems. Patent P2010509 Sodium vapor lamps. Mercury vapor lamps. Metal halide lamps.
More

Oil-immersed

The transformers are manufactured in compliance with IEC 60076-13 and, IEEE C57.1201 (or other required) standards. The core is made of magnetic sheets with high permeability and low loss rate with a joint assembly of 45º with cooling channels. All the winding of conductors is made of electrolytic copper of E-CU 99.9%. Depending on the design of the transformer, the winding can be continuous or with a disk at intervals, with multiple or simple propellers. The cooling channels are made ...
More

Cast Resin

Technical Features STANDARD The transformers are built in accordance with IEC 726 standards. CORE The core is built up of cold rollled oriented grain steel sheet with low specific losses, insulated on both sides by a thin inorganic coating (Carlyte). The sheets composing the core are cut at 45 degrees. Uniform pressing, stiffnes and solidity of the columns assure a low noise level. MEDIUM VOLTAGE WINDINGS The high voltage are made of  electrolitic aluminium conductors (wire or foil strip d...
More

Transformers and Three-Phase Autotransformers from 0.5 to 5,000 KVA. low voltage and dry.

  1.1. Construction features CLARKIA transformers have been designed and manufactured strictly in accordance with standards IEC 60076-6. Coils: Coiling is made of copper class H-Grade 2/thermal class H.200, according to IEC 60317-3. Insulation varnish for this copper is a polyester-IMIDA modified THEIC with a polyamide-IMIDA overcoat. This kind of winding wires are homologated according to UL-E103536 (NEMA MW-35C). All our coils lack insulation boards, which makes them ver...
More

Power Transformers

Three-phase transformers with copper and aluminum strip. Single-phase transformers with copper and aluminum strip. Ferroresonant transformers. Inductors with copper and aluminum strip.   Other models are made to customers’ specifications.
More