IEC-EN 60289
EC
Electrical features:
Inductance: 3.6 mH
Rated current: 1570 Amp.
Peak current: 2225 Amp.
500 Hz ripple: 300 Amp, PK/PK
Rated operational voltage: 5300 Vcc
Dielectric strength: 15 KV/50HZ/60 sec.
Weight: 2850 Kgs.
APPLICATION
DC Filter (chopper coil)
* Due to the wide range available, we can offer the inductor you need on request.
More
Author: clarkia1
Stabilized voltage and current sources
ELECTRICAL CHARACTERISTICS :
INPUT: 400V
OUTPUT 1: 0 A 60 Vac - 700 Amp
OUTPUT 2: 60 A 120 Vac - 350 Amp
REMOTE LOCAL CONTROL
CURRENT REGULATION
VOLTAGE REGULATION
RANGE 60V / 120V
MEASUREMENTS: 1200 x 800 x 500 mm (H x W x L)
FORCED VENTILATION
PROTECTION: IP.20
APPROXIMATE WEIGHT: 500 Kg
* Debido a la amplia gama existente, sobre demanda podemos ofrecer la fuente que usted desee.
More
Single-phase Systems
Systems for Regulating Luminous Flux
Patent P2010509
More
Three-phase systems
Lighting Flow Regulation Systems.
Patent P2010509
Sodium vapor lamps.
Mercury vapor lamps.
Metal halide lamps.
More
Oil-immersed
The transformers are manufactured in compliance with IEC 60076-13 and, IEEE C57.1201 (or other required) standards.
The core is made of magnetic sheets with high permeability and low loss rate with a joint assembly of 45º with cooling channels.
All the winding of conductors is made of electrolytic copper of E-CU 99.9%.
Depending on the design of the transformer, the winding can be continuous or with a disk at intervals, with multiple or simple propellers.
The cooling channels are made ...
More
Cast Resin
Technical Features
STANDARD
The transformers are built in accordance with IEC 726 standards.
CORE
The core is built up of cold rollled oriented grain steel sheet with low specific losses, insulated on both sides by a thin inorganic coating (Carlyte). The sheets composing the core are cut at 45 degrees. Uniform pressing, stiffnes and solidity of the columns assure a low noise level.
MEDIUM VOLTAGE WINDINGS
The high voltage are made of electrolitic aluminium conductors (wire or foil strip d...
More
PHASE MOTOR STARTING TRANSFORMERS
Transformers and Three-Phase Autotransformers from 0.5 to 5,000 KVA. low voltage and dry.
1.1. Construction features
CLARKIA transformers have been designed and manufactured strictly in accordance with standards IEC 60076-6.
Coils:
Coiling is made of copper class H-Grade 2/thermal class H.200, according to IEC 60317-3.
Insulation varnish for this copper is a polyester-IMIDA modified THEIC with a polyamide-IMIDA overcoat. This kind of winding wires are homologated according to UL-E103536 (NEMA MW-35C).
All our coils lack insulation boards, which makes them ver...
More
Three Phase Water Cooled Transformers
Power Transformers
Three-phase transformers with copper and aluminum strip.
Single-phase transformers with copper and aluminum strip.
Ferroresonant transformers.
Inductors with copper and aluminum strip.
Other models are made to customers’ specifications.
More